• Phone

    86-531-81219803

  • Address

    No. 51 South Gongye Road, Jinan, Shandong, China

  • E-mail

    k@waimaotong.com

LatestProducts

                            Biobase4000 Fully Automated Elisa Processor, Elisa Analyzer with 4 Microplates

Biobase4000 Fully Automated Elisa Processor, Elisa Analyzer with 4 Microplates

automated microplates
INQUIRY PRECISE INQUIRY
Description

Basic Info
  • Model NO.: BIOBASE4000
  • Sample Rack: 24 Sample Tubes/Rack, at Most 25 Racks
  • Time to Dispense: 8 Minutes (Typical)
  • QC Racks: 24 Positions/QC Rack, at Most 25 Racks
  • Wash Containers: 4 Wash Buffers at 2.0L, with Level-Sensing
  • Reading System: 8 Independent Photometric Channels with Mono and B
  • Trademark: BIOBASE
  • Specification: CE SGS
  • Medical Devices Reg./Record No.: Lsyjxzz-2012-2400441
  • Primary Sample Tubes: 11.5-13mm
  • Reagent Racks: 2 Reagent Tanks(60ml)/ Rack, at Most 25 Racks
  • Pipetting: 8UL~1000UL,1UL Stepping
  • Waste Containers: 10L with Waste Full Sensor
  • Photometric Range: 0.000 ~3.000 Od
  • Transport Package: Wooden Case
  • Origin: China
Product Description
BIOBASE4000 Fully automated ELISA processor,Elisa Analyzer with 4 microplates

1 Robotic hand.
4 Pipetting probe, 1ul stepping (1000ul volumes).
Total 25 racks, arbitrary rack can be defined as sample or reagent on the software.
4 units 96 well microplates (pipetting,incubator,reading).
1 unit independent washer &reader( two 8 nozzle manifolds).
Model BIOBASE4000
Sample pipetting unit Sample rack 24 sample tubes/rack, at most 25 racks
Primary sample tubes 11.5-13mm
Pipetting 8ul~1000ul&comma; &lpar;10ul&rpar; CV<5&percnt;
Time to dispense 8 minutes &lpar;typical&rpar;&Hat;100ul of 96 samples to plate from sample tubes or dilution tubes&period;
Dispensing system 1 aspirating-dispensing probe with X-Y-Z movement&semi;dilution system with a syringe of 1000ul&comma; continuous flow washing station&period;
Reagent pipetting unit Reagent racks 2 reagent tanks&lpar;60ml&rpar;&sol; rack&comma; at most 25 racks
QC racks 24 positions&sol;QC rack&comma; at most 25 racks
Pipetting 8ul~1000ul&comma;1ul stepping&comma;
pipetting precision &lpar;100ul &rpar;CV≤0&period;5&percnt;
Time to dispense 2 minutes&lpar;typical&rpar;&Hat;100ul of 96 reagents to plate from reagent bottle
Washing unit Programmable Yes&lpar;options & parameters&rpar;
Wash containers 4 wash buffers at 2&period;0L&comma; with level-sensing
Waste containers 10L with waste full sensor
Washing system two 8 nozzle manifolds&comma; one to dispense and the other one to aspirate&semi;
Washing residual <2μl
Reading unit Reading system 8 independent photometric channels with mono and bichromatic reading capability
Photometric range 0&period;000 ~3&period;000 OD
Spectral range 400-700nm
Optical filters 2 precision filters &lpar;450and 630nm&rpar;&semi; 2 more on request &lpar;4 filters max&comma; 405 nm&comma; 450 nm&comma; 492 nm and 630 nm&rpar;
Reading inaccuracy inaccuracy±1&percnt; from 0&period;000 to 1&period;500 OD&comma; ±2&percnt; from 1&period;500 to 3&period;000 OD 
Incubation unit Incubators 4 independent units
Programmable Yes
Temperature range RT to 45 °C 
Temperature accuracy ±0&period;5ºC
Temperature staility ±0&period;5ºC
Software unit Software system Windows XP or Windows 7 or above&comma; LIS system available&comma; realize two-way data communications
Function application work list set up&comma; patient reports and result filing&semi; calibration curve &comma;storage for each carried out test
Data reduction cut-off &lpar;qualitative&rpar;
Physical Specification Power Supply AC220V&plus; 10&percnt;&comma;50&sol;60Hz&comma;450W 
Instrument Dimension 110&ast;72&ast;70cm &lpar;L&ast;W&ast;H&rpar;
Instrument Weight 100kg
Package Dimension 138&ast;91&ast;98cm&lpar;L&ast;W&ast;H&rpar;
Total Weight 150kg